Skip to main content
Version: 7.0.0

Filter repeating issues

SDK will not send repeating/ duplicate issues to Finotes dashboard if they occur within 6 hours in the same session.

Deprecation

The @Observe annotation based API is now deprecated and will be removed in a future version. Use issueRaiseFrequency key in @FnObserve instead of issueRaiseFrequencyInHours key in @Observe.

Finotes reports all issues to the dashboard, in some cases same issue may reoccur in the same device.

Finotes has an inbuilt mechanism to filter out repeated/duplicate issues from being reported (from the same device in a single session) for a set number of hours using issueRaiseFrequency property of @FnObserve annotation in Application class.

Default value is 6 hours. Minimum supported is 1 hour up to maximum of 24 hours.

Application Class:


@FnObserve(issueRaiseFrequency = 10)
public class BlogApp extends Application {
@Override
public void onCreate() {
super.onCreate();
Fn.init(this);
}
}